Many
Manuals
search
Kategorie
Marki
Strona główna
SenTech
Aparaty z pseudo lustrem
STC-A33A
Instrukcja Użytkownika
SenTech STC-A33A Instrukcja Użytkownika Strona 41
Pobierz
Podziel się
Dzielenie się
Dodaj do moich podręczników
Drukuj
Strona
/
67
Spis treści
BOOKMARKI
Oceniono
.
/ 5. Na podstawie
oceny klientów
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
STC-A
33
A
i. Trigger Mode (90fps, Binning, Full scanning)
Function
Mode
Frame
rate
Bi
nnig
Scanning
Method
Trigger Mode
Reset Mode
Trigger
Polarity
Exposure
Start Mode
Gamma
Sync
System
Settings
10H
11H
12H
Trigger
90fps
ON
Full
scanning
Edge preset
Non-Reset
Positive
Normal
1.0
Internal
9
0H
A
0H
00H
External
2
0H
0.45
Internal
A
0H
01H
External
2
0H
H reset
1.0
Internal
A
0H
10H
External
2
0H
0.45
Internal
A
0H
11H
External
2
0H
Negative
Normal
1.0
Internal
D
0H
A
0H
0
0H
External
2
0H
0.45
Internal
A
0H
01H
External
2
0H
H reset
1.0
Internal
A
0H
10H
External
2
0H
0.45
Internal
A
0H
11H
External
2
0H
V-Reset
Positive
Normal
1.0
Internal
9
1H
A
0H
00H
External
2
0H
0.45
Internal
A
0H
01H
External
2
0H
H reset
1.0
Internal
A
0H
10H
External
2
0H
0.45
Internal
A
0H
11H
External
2
0H
Negative
Normal
1.0
Internal
D
1H
A
0H
00H
External
2
0H
0.45
Internal
A
0H
01H
External
2
0H
H reset
1.0
Internal
A
0H
10H
External
2
0H
0.45
Internal
A
0H
11H
External
2
0H
Pulse width
Non-Reset
Positive
Normal
1.0
Internal
B
0H
A
0H
00H
External
2
0H
0.45
Internal
A
0H
01H
External
2
0H
H reset
1.0
Internal
A
0H
10H
External
2
0H
0.45
Internal
A
0H
11H
External
2
0H
Negative
Normal
1.0
Internal
F
0H
A0H
00H
External
2
0H
0.45
Internal
A
0H
01H
External
2
0H
H reset
1.0
Internal
A
0H
10H
External
2
0H
0.45
Internal
A
0H
11H
External
2
0H
V-Reset
Positive
Normal
1.0
Internal
B
1H
A
0H
00H
External
2
0H
0.45
Internal
A
0H
01H
External
2
0H
H reset
1.0
Internal
A
0H
10H
External
2
0H
0.45
Internal
A
0H
11H
External
2
0H
Negative
Normal
1.0
Internal
F
1H
A
0H
00H
External
2
0H
0.45
Internal
A
0H
01H
External
2
0H
H reset
1.0
Internal
A
0H
10H
External
2
0H
0.45
Internal
A
0H
11H
External
2
0H
Application Manu
al
36 of
60
Re
v1.0
1
2
...
36
37
38
39
40
41
42
43
44
45
46
...
66
67
STC-A33A
1
Application Manual
1
*continues on next page
3
Contents
3
Video out
10
No rmal m ode
17
Exposure time
17
Trigger mode No rmal m ode
17
Command No
28
Command Descriptions
28
scanning)
38
Komentarze do niniejszej Instrukcji
Brak uwag
Publish
Drukuj dokument
Drukuj stronę 41
Komentarze do niniejszej Instrukcji