STC-GE Series
Product Specifications 18 Rev 3.01
2. Power/IO Connector: Connector: HR10A-7R-6PB (Hirose) or equivalent.
This connector is for the DC power input and the input and output signals.
Pin Assignment:
Pin No.
Signal Name
IN/OUT
Signals
Initial Output
1
GND
IN
GND
2
IO_OUT1
OUT
+3.3V LVTTL
FrameTriggerWait
3
IO_OUT2
OUT
+3.3V LVTTL
ExposureActive
4
TRG_In-
IN
Isolated -
5
TRG_In+
IN
Isolated +
6
POWER IN
IN
+10.8 to +26.4 Vdc
a. Input Signal
TRG IN: Input the trigger signal
High: +3.0 to +26.4V
Low: Smaller than 1.0V
b. Output Signals
Set the output signals from the power/IO connector.
The following six output signals are selectable with the software or communication.
1) FrameTriggerWait
The user can check the camera condition (camera exposure and image output processing by the trigger
signal with this FrameTriggerWait signal).
a) High status (3.3V): No processing by the trigger signal. The camera accepts the trigger signal.
b) Low status (0V): The camera is exposed and the image output processes by the trigger signal.
The camera default setting is the input trigger signal is INVALID while at the low status of this signal. When
the exposure starts while the image output by the next trigger signal, please change the camera setting
(Device code: 00H, Command: 13H) to accept the trigger signal while the image outputs.
The noise appears on the image when the exposure begins while the image is output. The noise appears on
the image when the start exposure while the image is output. In this case, please change the “H reset” for
the exposure start mode (Device code: 00H, Command: 12H) to change the exposure start point to the next
HD timing.
2) UserOutput
The status of the UserOutput signal can change with the UserOutputValue.
3) ExposureActive
The user can check the exposure time with the ExposureActive signal.
a) High status (3.3V): The camera is exposing
b) Low status (0V): The camera is not exposed
4) TriggerAuxiliary
The TriggerAuxiliary signal is the input trigger signal.